APC MGE Galaxy 3500 15kVA 400V battery module
Start-up 5X8
Brand: APC
SKU: G35T15KH2B2S
£10,804.18
Price excl. VAT
£12,965.02
Price incl. VAT
Out of stock
Do you have any question about this product? Click here to contact our pre-sales consultant and make the right purchase.
Buy with confidence: honest stock, fair trade terms
Better prices with correct stock availability, and secure payments with full transparency.
- Aggregated live stock: availability shown is the combined aggregated stock of our warehouses and partner distributors, updated in real time. If it says available, it is available.
- No charge until confirmed: your payment is only reserved at checkout and is charged once your item is secured.
- 24-hour free cancellation: changed your mind? Cancel within 24 hours and the reserved payment is released in full.
- Stock sold out? Full refund: if an item becomes unavailable after you order, we cancel and release or refund 100% of your payment.
- From Our Warehouse to Your Door. every order is checked, packed at our warehouses and dispatched with DHL Express, UPS or FedEx as DDP – No customs or duties to pay. No hidden charges
- Fair cancellation and return terms: for late cancellations or returns of expensive, special-order items without a fault, a fee of up to 5-10% may apply, covering only actual shipping and handling costs to sustain our business. Faulty items and RMA cases are never charged. No late-payment fees, no interest ever. Full terms
NOTE: The information below is provided for your convenience only; the accuracy of the specifications cannot be guaranteed. However, if necessary, please check with us before purchasing. Data provided by 1 World Sync.
General
Output power
12000 W
Output power capacity
15 kVA
Input frequency
40/70 Hz
Battery technology
Sealed Lead Acid (VRLA)
Battery recharge time
5 h
Product colour
Black
Certification
CE,EN 50091-2,EN/IEC 62040-3,EN/IEC 62040-1-1,IEC 61000-3-2,IEC 61000-3-3,ISO 14001,ISO 9001,VFI-SS-111
Weight
402 kg
Package weight
433 kg
APC MGE Galaxy 3500 15kVA 400V with 2 Battery Modules. Output power capacity: 15 kVA, Output power: 12000 W, Input frequency: 40/70 Hz. Battery technology: Sealed Lead Acid (VRLA), Battery recharge time: 5 h. Product colour: Black, Certification: CE,EN 50091-2,EN/IEC 62040-3,EN/IEC 62040-1-1,IEC 61000-3-2,IEC 61000-3-3,ISO 14001,ISO.... Weight: 402 kg. Package weight: 433 kg
| Estimate Gross Weight | 433.0 |
|---|
https://www.apc.com/resource/include/techspec_index.cfm?base_sku=G35T15KH2B2S&ISOCountryCode=gb
APC MGE Galaxy 3500, 12 kW / 15 kVA,Input 400V 3PH / Output 400V, Extended runtime model.
Includes: Battery modules ship installed, Bolt down brackets, CD with software, Installation guide, Network Management Card, Power modules ship installed, Smart UPS signalling RS-232 cable, Start-Up Service, User Manual.
- Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
- Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
- Parallel-redundant capable
Power the connected equipment with multiple UPSs to increase system redundancy
Availability
- Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
- Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Parallel-capacity capable
Increases total power capacity by using multiple UPSs simultaneously.
- Advanced electrical features
Excellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high efficiency
- Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
- Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
- Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Manageability
- Built-in Web/SNMP management
Full-featured management via a Web browser as well as comprehensive management from a Network Management System.
- Environmental Monitoring
Prevent equipment failure from a full range of threatening environmental conditions.
- LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
- Audible alarms
Provides notification of changing utility power and UPS conditions.
APC MGE Galaxy 3500, 12 kW / 15 kVA,Input 400V 3PH / Output 400V, Extended runtime model.
Includes: Battery modules ship installed, Bolt down brackets, CD with software, Installation guide, Network Management Card, Power modules ship installed, Smart UPS signalling RS-232 cable, Start-Up Service, User Manual.
- Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
- Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
- Parallel-redundant capable
Power the connected equipment with multiple UPSs to increase system redundancy
Availability
- Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
- Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Parallel-capacity capable
Increases total power capacity by using multiple UPSs simultaneously.
- Advanced electrical features
Excellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high efficiency
- Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
- Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
- Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Manageability
- Built-in Web/SNMP management
Full-featured management via a Web browser as well as comprehensive management from a Network Management System.
- Environmental Monitoring
Prevent equipment failure from a full range of threatening environmental conditions.
- LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
- Audible alarms
Provides notification of changing utility power and UPS conditions.
0.0
0 review(s)
In the building · Real shipments · Real operations
Goods in. Goods out. Real Tech, Moving Daily.
A snapshot of the technology we receive, handle, pack and dispatch. These images are captured on site or at customer locations — not from a stock library.